COD Digester is the most accepted Thermoreactor for Determination of Chemical Oxygen Demand in Various Substances. Chemical Oxygen Demand (COD) is a Measure of the Capacity of Water to Consume Oxygen During the Decomposition of Organic Matter and the Oxidation of Inorganic Chemicals such as Ammonia and Nitrite. COD Measurements are Commonly made on Samples of Waste Waters or of Natural Waters Contaminated by Domestic or Industrial Wastes. Chemical Oxygen Demand is Measured as a Standardized Laboratory assay in which a closed Water Sample is Incubated with a Strong Chemical Oxidant Under Specific Conditions of Temperature and for a Particular Period of Time.High Performance and User Friendly Controls Combine to Produce a Specification Which Offers Exceptional Efficiency and Reliability. The Benefit to you-convenient, No Fuss Heating! Excellent Temperature Control. Uniform And Stable Heating New Compact Size
Technical Specification:
Controller | Microprocessor Based Digital Temperature Indicator cum Controller |
Display | LED with set value (SV) and Process value (PV) |
Heater Load | 1.0KW |
Tube Cavity | 40mm(Ø) x 65mm(D) |
No. of Cavaties | 15 holes to accommodate 15 samples |
Glass Tube Size | Supplied with 15 nos. of Glass Tubes of size 38mm(Ø) x 200mm |
Glass Air Condenser Size | Supplied with 15 nos. of air condensers of 600 mm length each. |
Sample Size | 20 ml |
Temperature Range Ambient | +5°C to 150°C |
Temperature Accuracy | ±1°C |
Sensor | RTD (Pt-100) |
Material External | Powder Coated CRC Steel |
Block | Polished Aluminium |
Tube Rack | 1 No. |
Power Supply | 230V AC, 50/60Hz |
Copyright 2017 MICROTEKNIK | All Rights Reserved
Microteknik has exports their product to the following countries: Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda,,Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burundi, Cabo Verde, Cambodia, Cameroon, Canada, Central African Republic (CAR), Chad, Chile, China, Colombia, Comoros, Democratic Republic of the Congo, Republic of the Congo, Costa Rica, Cote d'Ivoire, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Dominican Republic, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia, Fiji, Finland, France, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, India, Indonesia, Iran, Iraq, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya, Kiribati, Kosovo, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Libya, Liechtenstein, Lithuania, Luxembourg, Macedonia (FYROM), Madagascar, Malawi, Malaysia, Maldives, Mali, Malta, Marshall Islands, Mauritania, Mauritius, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Myanmar (Burma), Namibia, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Niger, Nigeria, North Korea, Norway, Oman, Pakistan, Palau, Palestine, Panama, Papua New Guinea, Paraguay, Peru, Philippines, Poland, Portugal,Qatar, Romania, Russia, Rwanda, Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Korea, South Sudan, Spain, Sri Lanka, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Taiwan, Tajikistan, Tanzania, Thailand, Timor-Leste, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda, Ukraine, United Arab Emirates (UAE), United Kingdom (UK), United States of America (USA), Uruguay, Uzbekistan, Vanuatu, Vatican City (Holy See), Venezuela, Vietnam, Yemen, Zambia, Zimbabwe