Melting Point

JEQ-21 : For determination of the melting point upto 3000C with Temperaure controller. Block made of aluminium bored with the dia meter to accept capillary for keeping specimen


See Enlarge



Ir Moisture Balance

JIR-01 : A basic method for determination of moisture content, measure percent by weighing and drying simultaneously. Infra Red radiation are reflected by a bulb and its temperature is controlled by a regulator.
The balance scale is divided in terms of moisture content on wet weight basic. Work on 220V 50Hz AC mains.
Specifications:-
Range : 0-100%
Accuracy : 0.2%
Weight : 20 Kg.
Sample weight : 5gm, 20gm, 25gm


See Enlarge



Tlc (thin Layer Chromatograph) Apparatus

Jtl-01 :This unit is based on Desaga German pattern having movable applicator with in built thickness arrangement between 0 to 2mm have the following components :-
a) Spreader (Applicator) made of Aluminium / electroplated brass.
b) Perspex Base size 114x23cm to support 5 glass plates of size
20 x 20cm and 2 plates of 20x5cm.
c) Plate Rack Aluminium for ten 20x20 cm plates.
d) Spotting Tern plate perspex.
e) Developing tank with lid.
f) T.L.C. plates set 20 x 20cm or 20 x 10 cm.
g) Micro-pipette.
h) Scriber for making lines.
i) Glass sprayer with rubber bellow.


See Enlarge



Deonizers

JDE-01 : The plant consists of One cation Exchanger column containing cation Exchanger Resin. One anion exchanger column containing anion exchanger Resin. Plant is mounted on M.S. stand with assembly of valves and tubing. One conductivity meter with cell to monitor the ionised solids of purified water and thus control the functions of demineralisation. The meter is direct reading having reading heavy range 0.40 microns/cm.
a) Cap. or flow rate 30 to 50 It/hr.
b) Cap. or flow rate 75 to 100 It/hr.


See Enlarge



Refrigerated Centrifuge

JEQ-6 (D) : Streamlined rectangular body with elegant panel and clear acrylic lockable lid. Complete with pilot lamp, continuously variable speed regulator, Digital speed-indicator, plug-cord to work on 220 V AC 50 Hz single phase. A hermatically sealed compressor for cooling from ambient to -200C. Temperature controlled by Digital Temp. Controller cum Indicator with accuracy 0.50C. Maximum speed 5000 RPM. The centrifuge has an electrical interlock to ensure that the unit can not run with cover open.
(a) Capacity : 8x15 ml. (b) Capacity : 12x15 ml.
(c) Capacity : 16x15 ml. (d) Capacity : 12x1.5 ml.
(e) Capacity : 16x1.5 ml. (f) Capacity : 8x50 ml.
Note : Use of suitable Voltage stablizer is a must.
Optional : Automatic Voltage Stabilizer 2 KVA.